44
3 SIGNALS AND WIRING
3.3 Explanation of power supply system
Wiring CNP1, CNP2, and CNP3
• For the wire sizes used for wiring, refer to the following.
Page 166 Selection example of wires
• When wiring, remove the power connectors from the servo amplifier.
• Insert only one wire or ferrule into each wire insertion hole on the power connectors.
To wire to CNP1, CNP2 and CNP3, use the servo amplifier power connectors that came with the amplifier.
Connector
■
MR-J5-10_ to MR-J5-100_
■
MR-J5-200_/MR-J5-350_
Connector Receptacle assembly
Applicable wire
Stripped length
[mm]
Open tool
Manufac
turer
Size
Insulator OD
CNP1
06JFAT-SAXGDK-K7.5 (LA)
AWG 18 to 14
3.9 mm or shorter
9
J-FAT-OT-K
JST
CNP2
05JFAT-SAXGDK-K5.0 (LA)
CNP3
03JFAT-SAXGDK-K7.5 (LA)
Connector Receptacle assembly
Applicable wire
Stripped length
[mm]
Open tool
Manufac
turer
Size
Insulator OD
CNP1
06JFAT-SAXGFK-XL (LA)
AWG 16 to 10
4.7 mm or shorter
11.5
J-FAT-OT-EXL
JST
CNP2
05JFAT-SAXGDK-H5.0 (LA)
AWG 18 to 14
3.9 mm or shorter
9
CNP3
03JFAT-SAXGFK-XL (LA)
AWG 16 to 10
4.7 mm or shorter
11.5
CNP2
CNP1
CNP3
CNP2
CNP1