3 SIGNALS AND WIRING
3.3 Explanation of power supply system
41
3
U/V/W (Connection destination: Servo motor power supply)
To prevent abnormal operation and malfunction, connect the servo amplifier power outputs (U/V/W) to the servo motor power
inputs (U/V/W) directly. Do not connect a magnetic contactor and others between them.
N- (Connection destination: Simple converter)
This terminal is used to connect a servo amplifier with a power regeneration converter, power regeneration common
converter, brake unit, or simple converter.
Page 149 MR-CM simple converter
(Connection destination: Protective earth (PE))
Connect a servo amplifier to the grounding terminal of a servo motor and to the protective earth (PE) of a cabinet.