8 USING STO FUNCTION [G] [A]
8.4 Detailed explanation of interfaces
223
8
■
When outputting two STO states by using one TOFB
*1 If the voltage drop (maximum of 5.2 V) interferes with the relay operation, apply high voltage (maximum of 26.4 V) from external source.
TOFCOM
TOFB2
TOFB1
Servo amplifier
If polarity of diode is
reversed, servo amplifier
will malfunction.
Load
24 V DC ± 10 %
*1
300 mA