236
7 FUNCTIONAL SAFETY PARAMETER DETAILS
7.3 Network parameters group ([Pr. PSC_ _ ])
7.3
Network parameters group ([Pr. PSC_ _ ])
[Pr. PSC01_Transmission interval monitor time (**SNC)]
Select the transmission interval monitor time for safety communication.
Set the transmission interval monitor time so that it matches the safety communication setting of the controller.
This functional safety parameter can be used only with the MR-J5-G-RJ and MR-J5D_-_G_.
[Pr. PSC03_Functional safety - Rotation direction selection/travel
direction selection (**SNPOL)]
The rotation/travel direction can be changed without changing the polarity of the command from the controller.
[Pr. PSC03.0_Rotation direction selection/travel direction selection]
Set this functional safety parameter to the same value as [Pr. PA14 Travel direction selection].
Refer to the following table for setting values.
If this functional safety parameter is set incorrectly, [AL. 537 Parameter setting range error (safety sub-function)] occurs.
This functional safety parameter can be used only with the MR-J5-G-RJ and MR-J5D_-_G_.
[Pr. PSC06_Safety verification code (**SAC)]
Set the safety verification code for safety communication.
Doing so sets the value used to identify the servo amplifier. Set the MAC address, etc. so that it is not identical to that of a
different servo amplifier.
Match the safety verification code to the value set in the safety communication setting of the master station. If this parameter
is set to a non-matching value, [AL. 580 Safety communication setting error (safety sub-function)] occurs.
When setting the MAC address, set the lower 8 digits.
This functional safety parameter can be used only with the MR-J5-G-RJ and MR-J5D_-_G_.
Initial value
Setting range
Setting method
Ver.
32 [ms]
16 to 1000
Common
B2
Initial value
Setting range
Setting method
Ver.
00000010h
Refer to the relevant detail No.
Each axis
Refer to the relevant detail No.
Initial value
Setting range
Ver.
0h
Refer to the text
B2
Setting value
Servo motor rotation direction/linear servo motor travel direction
At forward rotation pulse input
At reverse rotation pulse input
0
CCW or positive direction
CW or negative direction
1
CW or negative direction
CCW or positive direction
Initial value
Setting range
Setting method
Ver.
FFFFFFFFh
00000000h to FFFFFFFFh
Common
B2
Содержание MR-J5-G Series
Страница 2: ......
Страница 215: ...4 SERVO PARAMETER SETTING METHOD 4 2 Object dictionary 213 4 MEMO ...
Страница 226: ...224 6 NETWORK PARAMETER SETTING METHOD 6 1 Engineering tool MEMO ...
Страница 255: ...9 FUNCTIONAL SAFETY PARAMETER SETTING METHOD 9 1 Engineering tool 253 9 MEMO ...
Страница 259: ......