1 SERVO PARAMETER DETAILS
1.3 Gain/filter setting servo parameters group ([Pr. PB_ _ ])
51
1
[Pr. PB26.4_Gain switching 2 selection]
0: Disabled
1: Signal (CDP2/C_CDP2)
2: The same condition as [Pr. PB26.0 Gain switching selection]
When "1" is selected, the gain changes to "Gain after gain switching 2" by using the control command (C_CDP2) from the
controller or the input device CDP2 (Gain switching 2).
When "1" is set in [Pr. PB26.0] while "2" has been selected for this servo parameter, the gain changes to "Gain after gain
switching 2" by the control command (C_CDP2) from the controller or the input device CDP2 (Gain switching 2).
[Pr. PB26.5_Gain switching selection during a stop]
0: Gain switching 2 during a stop is disabled
1: Gain switching 2 during a stop is enabled
This servo parameter is enabled in the following condition: [Pr. PB26.4 Gain switching 2 selection] is set to "2" (the same
condition as [Pr. PB26.0 Gain switching selection]) and [Pr. PB26.0] is set to "5" (command direction) in the position mode and
positioning mode.
Initial value
Setting range
Ver.
0h
Refer to the text