138
1 SERVO PARAMETER DETAILS
1.7 Extension setting 3 servo parameters group ([Pr. PF_ _ ])
[Pr. PF83_Drive recorder - Trigger operation axis common
selection (**DRTAX)]
[Pr. PF83.0_Drive recorder - Trigger axis common selection]
For when the trigger conditions of the drive recorder are met on a multi-axis servo amplifier, select whether to store only the
data of the axis in which the conditions are met, or to store the data of all axis.
0: Disabled
1: Enabled
When "0" (disabled) is set, the drive recorder data is stored on the axis in which the trigger conditions are met.
If "1" (enabled) is set, the trigger conditions will be regarded as having been met on all axes even if the trigger conditions have
only been met on Axis A, B, or C. The trigger conditions are not regarded as having been met on axes for which "0" (automatic
setting mode) is set in [Pr. PF80.0 Drive recorder - Operation mode selection].
The servo parameter is disabled in the following conditions.
• The MR-J5-_G_ or MR-J5D1-_G_ is used,
• The axis of a multi-axis servo amplifier which has [Pr. PF80.0] set to "0" (automatic setting)" is used,
• The axis of a multi-axis servo amplifier which has [Pr. PF80.0] set to "1" (manual setting mode) and [Pr. PF82.0] set to "0"
(alarm trigger) is used.
Initial value
Setting range
Setting method
Ver.
00000000h
Refer to the relevant detail No.
Common
Refer to the relevant detail No.
Initial value
Setting range
Ver.
0h
Refer to the text
A0