1 SERVO PARAMETER DETAILS
1.7 Extension setting 3 servo parameters group ([Pr. PF_ _ ])
137
1
[Pr. PF82.2_Drive recorder - Trigger operation selection 1]
Select whether sampling starts when the signal output for the drive recorder channel set in [Pr. PF84.0-1 Drive recorder -
Trigger channel selection 1] exceeds or falls below the set trigger level.
When [Pr. PF80.0 Drive recorder - Operation mode selection] is set to "0" (automatic setting mode), or [Pr. PF80.0] is set to
"1" and [Pr. PF82.0] is set to "0", the setting value of this servo parameter is disabled.
0: Rising
1: Falling
[Pr. PF82.3_Drive recorder - Trigger operation selection 2]
Select whether sampling starts when the signal output for the drive recorder channel set in [Pr. PF84.2-3 Drive recorder -
Trigger channel selection 2] exceeds or falls below the set trigger level.
The servo parameter is disabled in the following conditions.
• [Pr. PF80.0 Drive recorder - Operation mode selection] is set to "0" (automatic setting mode)
• [Pr. PF82.0 Drive recorder - Trigger mode selection] is set to "0" (alarm trigger)
• [Pr. PF82.1 Drive recorder - Trigger binding condition selection] is set to "0" (disabled)
0: Rising
1: Falling
Initial value
Setting range
Ver.
0h
Refer to the text
A0
Initial value
Setting range
Ver.
0h
Refer to the text
A0
Содержание MR-J5-G Series