1 SERVO PARAMETER DETAILS
1.4 Extension setting servo parameters group ([Pr. PC_ _ ])
81
1
[Pr. PC29_Function selection C-B (*COPB)]
[Pr. PC29.0_[AL. 0E2.2 Servo motor temperature warning 2] selection]
Select whether to enable or disable [AL. 0E2.2 Servo motor temperature warning 2] when a servo motor with a batteryless
absolute position encoder is used.
0: Enabled
1: Disabled
[Pr. PC29.3_Torque POL reflection selection]
When this servo parameter setting is enabled, setting of [Pr. PA14 Travel direction selection] changes the polarities in the
following items: torque command ([Target torque (Obj. 6071h)] and [Torque demand value (Obj. 6074h)]), torque limit value
([Positive torque limit value (Obj. 60E0h)] and [Negative torque limit value (Obj. 60E1h)]), and torque feedback ([Torque actual
value (Obj. 6077h)]).
0: Enabled
1: Disabled
Initial value
Setting range
Setting method
Ver.
00101000h
Refer to the relevant detail No.
Each axis
Refer to the relevant detail No.
Initial value
Setting range
Ver.
0h
Refer to the text
A0
Initial value
Setting range
Ver.
1h
Refer to the text
A0
Setting value
Selection of servo motor rotation direction/linear servo motor
travel direction
[Pr. PC29.3]
[Pr. PA14]
Torque handled by the
controller: positive
Torque handled by the
controller: negative
0: Enabled
0
CCW or positive direction
(Forward rotation in power running
mode, reverse rotation in
regenerative mode)
CW or negative direction
(Reverse rotation in power running
mode, forward rotation in
regenerative mode)
1
CW or negative direction
(Reverse rotation in power running
mode, forward rotation in
regenerative mode)
CCW or positive direction
(Forward rotation in power running
mode, reverse rotation in
regenerative mode)
1: Disabled
0
CCW or positive direction
(Forward rotation in power running
mode, reverse rotation in
regenerative mode)
CW or negative direction
(Reverse rotation in power running
mode, forward rotation in
regenerative mode)
1