1 SERVO PARAMETER DETAILS
1.5 I/O setting servo parameters group ([Pr. PD_ _ ])
[Pr. PD14_Function selection D-3 (*DOP3)]
[Pr. PD14.1_Output device status at warning occurrence]
Select ALM (Malfunction) output status at warning occurrence.
[Pr. PD15_Driver communication setting (**IDCS)]
[Pr. PD15.0_Master axis operation selection]
0: Disabled (master-slave operation function is not used)
1: Enabled (set this servo amplifier for the master axis)
To set the servo amplifier for the slave axis, set "0".
This servo parameter is enabled only with 1-axis servo amplifiers.
When this servo parameter is set to "1" (enabled) on a multi-axis servo amplifier, [AL. 037 Parameter error] occurs.
[Pr. PD15.1_Slave axis operation selection]
0: Disabled (master-slave operation function is not used)
1: Enabled (set this servo amplifier for the slave axis)
To set the servo amplifier for the master axis, set "0".
This servo parameter is enabled only with 1-axis servo amplifiers.
When this servo parameter is set to "1" (enabled) on a multi-axis servo amplifier, [AL. 037 Parameter error] occurs.
Initial value
Setting range
Setting method
Ver.
00000000h
Refer to the relevant detail No.
Each axis
Refer to the relevant detail No.
Initial value
Setting range
Ver.
0h
Refer to the text
A0
Setting value
Device status
0
1
Initial value
Setting range
Setting method
Ver.
00000000h
Refer to the relevant detail No.
Each axis
Refer to the relevant detail No.
Initial value
Setting range
Ver.
0h
Refer to the text
D0
Initial value
Setting range
Ver.
0h
Refer to the text
D0
OFF
ON
OFF
ON
WNG
ALM
Warning occurrence
OFF
ON
OFF
ON
WNG
ALM
Warning occurrence