76
1 SERVO PARAMETER DETAILS
1.4 Extension setting servo parameters group ([Pr. PC_ _ ])
[Pr. PC19_Function selection C-6 (*COP6)]
[Pr. PC19.0_[AL. 099 Stroke limit warning] selection]
Enable or disable [AL. 099 Stroke limit warning].
When "Disabled" is selected, [AL. 099] does not occur while LSP (Forward rotation stroke end) or LSN (Reverse rotation
stroke end) is off, but the operation will be stopped with the stroke limit.
0: Enabled
1: Disabled
[Pr. PC19.4_Output open-phase detection selection]
Enable or disable the detection of output open-phase detection function.
0: Disabled
1: Enabled
[Pr. PC19.6_Output open phase - Judgment speed selection]
0: Servo motor speed
1: Speed command
When "0" (servo motor speed) is set, the value of the servo motor speed is used for the speed judgment of the output open-
phase detection.
When "1" (speed command) is set, the speed command value is used for the speed judgment of the output open-phase
detection.
In the torque mode, set "0" (servo motor speed). When "1" (speed command) is set, [AL. 139.2 Output open-phase error]
does not occur.
Initial value
Setting range
Setting method
Ver.
00000000h
Refer to the relevant detail No.
Each axis
Refer to the relevant detail No.
Initial value
Setting range
Ver.
0h
Refer to the text
A0
Initial value
Setting range
Ver.
0h
Refer to the text
A0
Initial value
Setting range
Ver.
0h
Refer to the text
A0
Содержание MR-J5-G Series
Страница 2: ......
Страница 215: ...4 SERVO PARAMETER SETTING METHOD 4 2 Object dictionary 213 4 MEMO ...
Страница 226: ...224 6 NETWORK PARAMETER SETTING METHOD 6 1 Engineering tool MEMO ...
Страница 255: ...9 FUNCTIONAL SAFETY PARAMETER SETTING METHOD 9 1 Engineering tool 253 9 MEMO ...
Страница 259: ......