11 - 42
11. OPTIONS AND AUXILIARY EQUIPMENT
11.13 Surge absorbers (Recommended)
A surge absorber is required for the electromagnetic brake. Use the following surge absorber or equivalent.
Insulate the wiring as shown in the diagram.
Maximum rating
Permissible circuit
voltage
Surge
immunity
Energy
immunity
Rated
power
Maximum
limit voltage
Static
capacity
(reference
value)
Varistor voltage
rating (range) V1mA
AC[Vma]
DC[V]
[A]
[J]
[W]
[A]
[V]
[pF]
[V]
140
180
(Note)
500/time
5
0.4
25
360
300
220
(198 to 242)
Note. 1 time 8
20 s
(Example) ERZV10D221 (Matsushita Electric Industry)
TNR-10V221K (Nippon chemi-con)
Outline drawing [mm] (ERZ-C10DK221)
13.5
16
.5
3.
0
or
l
e
s
s
30
.0
or
m
o
re
Crimping terminal
for M4 screw
Vinyl tube
4.7 1.0
0.8
11.14 Noise reduction techniques
Noises are classified into external noises which enter the servo amplifier to cause it to malfunction and those
radiated by the servo amplifier to cause peripheral devices to malfunction. Since the servo amplifier is an
electronic device which handles small signals, the following general noise reduction techniques are required.
Also, the servo amplifier can be a source of noise as its outputs are chopped by high carrier frequencies. If
peripheral devices malfunction due to noises produced by the servo amplifier, noise suppression measures
must be taken. The measures will vary slightly with the routes of noise transmission.
(1) Noise reduction techniques
(a) General reduction techniques
Avoid laying power lines (input and output cables) and signal cables side by side or do not bundle
them together. Separate power lines from signal cables.
Use shielded, twisted pair cables for connection with the encoder and for control signal transmission,
and connect the shield to the SD terminal.
Ground the servo amplifier, servo motor, etc. together at one point (refer to Section 3.12).
(b) Reduction techniques for external noises that cause the servo amplifier to malfunction
If there are noise sources (such as a magnetic contactor, an electromagnetic brake, and many relays
which make a large amount of noise) near the servo amplifier and the servo amplifier may malfunction,
the following countermeasures are required.
Provide surge absorbers on the noise sources to suppress noises.
Attach data line filters to the signal cables.
Ground the shields of the encoder connecting cable and the control signal cables with cable clamp
fittings.
Содержание MR-J3-B
Страница 1: ...General Purpose AC Servo MODEL MR J3 B SERVO AMPLIFIER INSTRUCTION MANUAL SSCNET Compatible J3 Series ...
Страница 13: ...A 12 MEMO ...
Страница 41: ...2 6 2 INSTALLATION MEMO ...
Страница 141: ...7 16 7 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 215: ...11 52 11 OPTIONS AND AUXILIARY EQUIPMENT MEMO ...