5 - 8
5. PARAMETERS
(1) For output pulse designation
Set " 0 " (initial value) in parameter No. PC03.
Set the number of pulses per servo motor revolution.
Output pulse set value [pulses/rev]
For instance, set "5600" to Parameter No. pa15, the actually output A/B-phase pulses are as indicated
below:
4
5600
A B-phase output pulses
1400[pulse]
(2) For output division ratio setting
Set " 1 " in parameter No. PC03.
The number of pulses per servo motor revolution is divided by the set value.
Output pulse
[pulses/rev]
Resolution per servo motor revolution
Set value
For instance, set "8" to Parameter No. pa15, the actually output A/B-phase pulses are as indicated
below:
A B-phase output pulses
8192[pulse]
8
262144
4
1