3 - 12
3. SIGNALS AND WIRING
(b) Termination of the cables
1) CNP1 CNP3
Solid wire: After the sheath has been stripped, the cable can be used as it is.
7mm
(0.276in)
Sheath
Core
Twisted wire: Use the cable after stripping the sheath and twisting the core. At this time, take care to avoid
a short caused by the loose wires of the core and the adjacent pole. Do not solder the core as
it may cause a contact fault. Alternatively, a bar terminal may be used to put the wires
together.
Cable size
Bar terminal type
[mm
2
]
AWG
For 1 cable
For 2 cables
Crimping tool
Maker
0.34
22
AI0.34-8TQ
0.5
20
AI0.5-8WH
AI-TWIN2
0.5-8WH
0.75
18
AI0.75-8GY
AI-TWIN2
0.75-8GY
1
18
AI1-8RD
AI-TWIN2
1-8RD
1.5
16
AI1.5-8BK
AI-TWIN2
1.5-8BK
2.5
14
AI2.5-8BU
AI-TWIN2
2.5-8BU
CRIMPFOX-ZA3
Phoenix Contact
2) CNP2
CNP2 is the same as MR-J3-100B or smaller capacities. Refer to (1) (b) in this section.
(c) As twin type connector for CNP2 (L
11
, L
21
) is the same as MR-J3-100B or smaller.
Refer to (1) (C) in this section.