1 - 4
1. FUNCTIONS AND CONFIGURATION
1.3 Servo amplifier standard specifications
Servo Amplifier
MR-J3-
Item
10B
20B
40B
70B
100B
200B
350B
500B
700B
10B1
20B1
40B1
Voltage/frequency
3-phase 200 to 230VAC,
50/60Hz or 1-phase 230VAC,
50/60Hz
3-phase 200 to 230VAC, 50/60Hz
1-phase 100V to
120VAC, 50/60Hz
Permissible voltage fluctuation
3-phase 200 to 230VAC: 170
to 253VAC
1-phase 230VAC: 207 to
253VAC
3-phase 170 to 253VAC
1-phase 85 to 132VAC
Permissible frequency fluctuation
Within 5%
Power supply capacity
Refer to Section 10.2
P
o
w
e
r s
uppl
y
Inrush current
Refer to Section 10.5
Voltage, frequency
1-phase 200 to 230VAC, 50/60Hz
1-phase 100 to
120VAC, 50/60Hz
Permissible voltage
fluctuation
1-phase 170 to 253VAC
1-phase 85 to 132VAC
Permissible frequency
fluctuation
Within 5%
Input
30W
45W
30W
Control circuit
power supply
Inrush current
Refer to Section 11.5
Voltage, frequency
DC24V 10%
Interface power
supply
Power supply capacity
(Note 1) 150mA or more
Control System
Sine-wave PWM control, current control system
Dynamic brake
Built-in
Protective functions
Overcurrent shut-off, regenerative overvoltage shut-off, overload shut-off (electronic thermal
relay), servo motor overheat protection, encoder error protection, regenerative brake error
protection, undervoltage, instantaneous power failure protection, overspeed protection,
excessive error protection
Structure
Self-cooled, open
(IP00)
Force-cooling, open (IP00)
Self-cooled, open
(IP00)
[
] (Note 2) 0 to 55 (non-freezing)
During
operation
[
] 32 to 131 (non-freezing)
[
]
20 to 65 (non-freezing)
Ambient
temperature
In storage
[
]
4 to 149 (non-freezing)
In operation
Ambient
humidity
In storage
90%RH or less (non-condensing)
Ambient
Indoors (no direct sunlight)
Free from corrosive gas, flammable gas, oil mist, dust and dirt
Altitude
Max. 1000m (3280ft) above sea level
E
n
vi
ronm
ent
Vibration
5.9 [m/s
2
] or less
[kg]
0.8
0.8
1.0
1.4
1.4
2.3
2.3
4.6
6.2
0.8
0.8
1.0
Mass
[lb]
1.8
1.8
2.2
3.1
3.1
5.071
5.071
10.1
13.7
1.8
1.8
2.2
Note 1. 150mA is the value applicable when all I/O signals are used. The current capacity can be decreased by reducing the number of
I/O points.
2. When mounting the servo amplifiers closely, operate them at the ambient temperatures of 0 to 45
or at 75% or a smaller
effective load ratio.
Содержание MR-J3-B
Страница 1: ...General Purpose AC Servo MODEL MR J3 B SERVO AMPLIFIER INSTRUCTION MANUAL SSCNET Compatible J3 Series ...
Страница 13: ...A 12 MEMO ...
Страница 41: ...2 6 2 INSTALLATION MEMO ...
Страница 141: ...7 16 7 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 215: ...11 52 11 OPTIONS AND AUXILIARY EQUIPMENT MEMO ...