11 - 41
11. OPTIONS AND AUXILIARY EQUIPMENT
11.11 Power factor improving reactors
The power factor improving reactors improve the phase factor by increasing the form factor of servo amplifier's
input current.
It can reduce the power capacity.
The input power factor is improved to be about 90%. For use with a 1-phase power supply, it may be slightly
lower than 90%.
In addition, it reduces the higher harmonic of input side.
When using power factor improving reactors for two servo amplifiers or more, be sure to connect a power
factor improving reactor to each servo amplifier.
If using only one power factor improving reactor, enough improvement effect of phase factor cannot be
obtained unless all servo amplifiers are operated.
Z
3-phase
200 to 230VAC
NFB
FR-BAL
Servo amplifier
MR-J3- B
R
S
T
X
Y
Z
L
1
L
2
L
3
MC
1-phase
230VAC
NFB
FR-BAL
Servo amplifier
MR-J3- B
R
S
T
X
Y
Z
L
1
L
2
L
3
MC
W
W1
C
R X S Y T Z
H
5
D1
Installation screw
D
5
[Unit : mm]
(Note)
1-phase
100 to120VAC
NFB
FR-BAL
Servo amplifier
MR-J3- B1
R
S
T
X
Y
L
1
Blank
MC
L
2
Note. For the 1-phase 230V power supply, Connect the power supply to L1, L2 and leave L3 open.
Dimensions [mm]
Servo amplifier
Model
W
W1
H
D
D1
C
Mounting
screw size
Terminal
screw size
Mass
[kg (lb)]
MR-J3-10B/20B/10B1
FR-BAL-0.4K
135
120
115
59
45
-2.5
0
7.5
M4
M3.5
2.0 (4.4)
MR-J3-40B/20B1
FR-BAL-0.75K
135
120
115
69
57
-2.5
0
7.5
M4
M3.5
2.8 (6.17)
MR-J3-60B/70B/40B1
FR-BAL-1.5K
160
145
140
71
55
-2.5
0
7.5
M4
M3.5
3.7 (8.16)
MR-J3-100B
FR-BAL-2.2K
160
145
140
91
75
-2.5
0
7.5
M4
M3.5
5.6 (12.35)
MR-J3-200B
FR-BAL-3.7K
220
200
192
90
70 5
10
M5
M4
8.5 (18.74)
MR-J3-350B
FR-BAL-7.5K
220
200
194
120
100 5
10
M5
M5
14.5 (32.0)
MR-J3-500B
FR-BAL-11K
280
255
220
135
100
12.5
M6
M6
19 (41.9)
MR-J3-700B
FR-BAL-15K
295
270
275
133
110
12.5
M6
M6
27 (59.5)
11.12 Relays (Recommended)
The following relays should be used with the interfaces:
Interface
Selection example
Relay used for digital input command signals (interface DI-1) To prevent defective contacts , use a relay for small signal
(twin contacts).
(Ex.) Omron : type G2A , MY
Relay used for digital output signals (interface DO-1)
Small relay with 12VDC or 24VDC of 40mA or less
(Ex.) Omron : type MY