5 - 10
5. PARAMETERS
No.
Symbol
Name
Initial Value
Unit
PB42
For manufacturer setting
1125
PB43
0004h
PB44
0.0
PB45
0000h
5.2.2 Detail list
No.
Symbol
Name and Function
Initial
Value
Unit
Setting
Range
PB01
FILT
Adaptive tuning mode (adaptive filter )
Select the setting method for filter tuning. Setting this parameter to " 1" (filter
tuning mode 1) automatically changes the machine resonance suppression filter 1
(parameter No. PB13) and notch shape selection (parameter No. PB14).
Machine resonance point
Notch frequency
Frequency
Frequency
Respons
e
of
mecha
n
ic
al
s
yst
em
Not
c
h dept
h
Filter tuning mode selection
0 0 0
0000h
Setting
Filter adjustment mode
Automatically set parameter
0
Filter OFF
(Note)
1
Filter tuning mode
Parameter No. PB13
Parameter No. PB14
2
Manual mode
Note. Parameter No. PB13 and PB14 are fixed to the initial values.
When this parameter is set to " 1", the tuning is completed after positioning is
done the predetermined number or times for the predetermined period of time, and the
setting changes to " 2". When the filter tuning is not necessary, the setting
changes to " 0". When this parameter is set to " 0", the initial values are set
to the machine resonance suppression filter 1 and notch shape selection. However, this
does not occur when the servo off.