5.1.5 Forced stop input selection
Parameter
No.
Symbol
Name
Initial Value
Unit
Setting Range
PA04
*AOP1 Function selection A-1
0000h
Refer to the text.
POINT
This parameter is made valid when power is switched off, then on after
setting, or when the controller reset has been performed.
The servo forced stop function is voidable.
Selection of servo forced stop
0: Valid (Forced stop (EM1) is used.)
1: Invalid (Forced stop (EM1) is not used.)
Parameter No.PA04
0
0
0
When not using the forced stop (EM1) of servo amplifier, set the selection of servo forced stop to Invalid (
1). At this time, the forced stop (EM1) automatically turns on inside the servo amplifier.