C-64
POWER SUPPLY
220-240V 50Hz
2
1
TB5(M-NET)
(*1)
Optional Remote controller
A
B
S
(PZ-60DR-E)
*When the optional Remote Controller PZ-60DR-E
cable
(non-polar)
24VDC 2A 5VDC 100mA
MAX 240VAC 2A MIN 220VAC 100mA
L
L
N
N
M
1
M
2
PE
monitor output
Operation or Delay1
LS
TR
TM1
CN1
CN2
CN7
BLUE
BROWN
YELLOW
RED
BROWN
RED
BLUE
BLUE
EXHAUST
FAN MOTOR
SUPPLY
FAN MOTOR
WHITE
ORANGE
YELLOW
GREY
BLACK
C
C
SA2
SA1
SW2
SW5
SW1
CN6
ORANGE
ORANGE
TH1(OA)
TH2(RA)
ORANGE
ORANGE
ORANGE
ORANGE
TM2
BROWN
PZ-
60DR-E
Transmission
TB5
TM3
TAB3
TAB5
CN10
CN9
TAB1
TAB2
Isolator
X12 X11
CN32
X10
S
B
A
9
2
1
CN5
3
2
1
6
7
8
10
CN16
TM4
RED
GREEN/YELLOW
BROWN
output
7
,
8
Malfunction monitor
monitor output
6
,
7
By-pass or Delay2
MAX 240VAC 1A
12V or 24V DC
Mr.Slim
(non-polar)
2nd remote controller
(Max.2remote controllers installable cable)
2nd LOSSNAY unit (Up to max 15 units)
MELANS
cable
transmission
M-NET
Sheild Wire
24VDC 1A
MAX 240VAC 1A
5VDC 100mA
MIN 220VAC 100mA
Unchanged a-conntact
1
3
External control input
TM4
(Max.2 remote controllers
2nd remote controller
Sheild Wire
cable
transmission
M-NET
2nd or later main units
installable)
(*1)PZ-41SLB-E and PZ-52SF-E cannot
be used when using PZ-60DR-E
is used as the M-NET System ,connect it to
of TM4 terminal block,and connect M-NET
transmission wire to , on TB5 terminal
block.
1
2
A
B
GM
CN16
(Unchanged a-conntact)
HI
LO
EXTRA-LO
By-pass
M
C
C
(*2) LGH-100RX
5
has 2
capacitors per mortor
as following drawing.
(*2)
(*2)
(*1)
BROWN
RED
ORANGE
YELLOW
GREEN
11. Installation method
11.1 Electrical installation
With this product, the wiring installation method will vary according to the design of the system.
Perform electrical installation to meet local electrical regulations.
* Always use double insulated PVC cable for the transmission cables.
* Wiring work must be performed by qualified professionals.
* All supply circuits must be disconnected before obtaining access to the terminal devices
11.1.1 Names of components in control box
LGH-15 to 100 RX
5
TM1
LED1
LED4
LED2
SW1
SW2, SW5
SA1, SA2
TM4
TB5
TM2
TM3
11.1.2 Wire connection diagram
* Connect the wires shown as thick lines.
* Be sure to connect the ground wire.
* A power supply isolator must be installed when wiring power sup-
ply to unit.
* Always use a single pole isolator for the main switch power con-
nection.
Definitions of symbols
M1:
Motor for exhaust fan
M2:
Motor for supply fan
C:
Capacitor
GM:
Motor for By-pass movement
LS:
Microswitch
TH1:
Thermistor for outside air
TH2:
Thermistor for return air
SW1:
Switch (Main/Sub change)
SW2,5: Switch (Function selection)
TM1:
Terminal block
(Power supply)
TM2:
Terminal block
(External control input)
TM3:
Terminal block
(Monitor output)
TM4:
Terminal block
(Transmission cable and
monitor output)
TB5:
Terminal block
(M-NET Transmission cable)
TAB1,TAB2:Connector (Power supply)
TR:
Control circuit transformer
X10:
Relay contact
X11:
Relay contact
X12:
Relay contact
CN1:
Connector
(Transformer primary)
CN2:
Connector
(Transformer secondary)
CN5:
Connector (Thermistor)
CN6:
Connector (Microswitch)
CN7:
Connector
(Motor for By-pass operation)
TAB3:
Tab connector
(Fan motor)
TAB5:
Tab connector
(Fan motor)
CN9:
Connector (Fan motor)
CN10: Connector (Fan motor)
CN16: Connector
(High/Low/Extra-Low/BY-
PASS switch)
CN32: Connector
(Remote control selection)
SA1:
Address setting rotary
switch (10 digit)
SA2:
Address setting rotary
switch (1 digit)
LED1: Inspection indicator lamp
LED2: Inspection indicator lamp
LED4: Power supply indicator
lamp
SYMBOL
:Terminal block
: Connector
: Board insertion
connector or fas-
tening connector
of control board.