Expansion Stages and System Capacity
85
Mitel SMB Controller
syd-0657/2.0 – R6.0 – 09.2018
– LEDs on terminals and expansion key modules: 20% active.
– Wire diameter: 0.5 mm
– Line length: 200 m
The table below shows the average power requirements of the terminals for a line
length of approx. 200 m and a wire diameter of 0.5 mm.
Tab. 30
Average power requirements of terminals
Tip
With the planning application Mitel CPQ the power supply available for terminals is checked
automatically.
3. 4. 10. 2
Power supply per terminal interface
The power supply per terminal interface is determined by the interface type. The inter-
face load depends on the following variables:
• Terminals used incl. auxiliary devices
• Bus configuration
• Line length and conductor cross-section
Terminals
Socket
Output P [mW]
MiVoice 5360
1)
1) Although no longer available, the phone is still supported.
DSI-AD2 interface
280
MiVoice 5361
DSI-AD2 interface
680
MiVoice 5370
DSI-AD2 interface
680
MiVoice 5380
DSI-AD2 interface
820
MiVoice 5370, MiVoice 5380 with power supply
unit
DSI-AD2 interface
0
Expansion key module MiVoice M530
MiVoice 5370
110
Expansion key module MiVoice M530
MiVoice 5380
120
Expansion key module MiVoice M535
MiVoice 5370, MiVoice 5380
0
2)
2) An MiVoice M535 always requires a power supply unit
Radio unit without power supply unit SB-4+
DSI-AD2 interface
1500
3)
3) The value applies to radio units with hardware version "-2". The value for hardware version "-1" is 300 mW
lower.
Radio unit without power supply unit SB-8
2 DSI-AD2 interfaces
1350
4)
4) The value applies to each interface and to radio units with hardware version "-2". The value per interface for
radio units with hardware version "-1" is 150 mW lower.
Radio unit with power supply unit SB-4+/SB-8
1 or 2 DSI-AD2 interfaces
< 100
ISDN terminal
BRI-S interface
approx. 500
5)
5) The value depends greatly on the terminal type.
Analogue terminals
FXS interface
approx. 500