Operation and Maintenance
199
Mitel SMB Controller
syd-0657/2.0 – R6.0 – 09.2018
Tab. 83
Combination patterns during start-up
As soon as pattern [5] is showed, the start-up phase is completed and the SMB Con-
troller is in normal mode. You are able to log into the SMB Controller Manager. The
MiVoice Office 400 application software is now starting up and after a while you are
able to log in to MiVoice Office 400 WebAdmin.
6. 4. 3. 2
Normal mode
The SMB Controller is in normal mode when the SMB Controller system software is up
an running without error. The LED combination pattern [6] is displayed.
If there is a problem with the temperature inside the housing of the SMB Controller
(overheating) and/or a problem with the fan, it is signalled with the PWR LED turning
from green to orange (pattern [7]). Details of the problem can be found in the SMB
Controller Manager.
If applications are loaded an running, there might be some additional information avail-
able, indicated with the LED F0 - F6. Each LED is assigned to an application. The F0
LED is assigned to the MiVoice Office 400 application:
• If the F0 LED lights up orange (pattern [8]), the default IP address is active.
• If the F0 LED lights up red (pattern [9]), there is an error in the MiVoice Office 400
application. Details of the error can be found in the SMB Controller Manager.
Tab. 84
Normal mode with additional information
No. PWR
F0
F1
F2
F3
F4
F5
F6
SYS
Dura-
tion
Meaning
[1]
~11
Power is on
[2]
~2
Time frame to start emergency
mode
[3]
~2
Time frame to start Factory
Default of Call Manager
[4]
~50
Loading SMB Controller sys-
tem software
[5]
Normal mode, SMB Controller
is up and running
No. PWR
F0
F1
F2
F3
F4
F5
F6
SYS Meaning
[6]
Normal mode, SMB Controller is up and
running.
G
–
–
–
–
–
–
–
–
G
R
–
–
–
–
–
–
–
G
G
–
–
–
–
–
–
–
G
–
–
–
–
–
–
–
–
G
–
–
–
–
–
–
–
–
G
G
–
–
–
–
–
–
–
–
G