Operation and Maintenance
189
Mitel SMB Controller
syd-0657/2.0 – R6.0 – 09.2018
The system configuration data (User No., User configuration, etc.) of the terminals on
the new ports is created as new data (default values).
Tab. 79
Example: Expanding the number of terminal or network interfaces
6. 3. 3. 4
Change slot
Interface cards can be moved to a different slot. The terminal configuration data of the
system phones can be transferred.
Procedure:
1. Change the slot and put the system into operation again. Similar procedure as de-
scribed in "Replacing a defective interface card", page 187.
Note:
The wiring adapter must also be changed to the corresponding slot.
2. Connect the system terminals to the ports of the new slot.
3. Reconfigure the port assignment.
4. In the WebAdmin view
Cards and modules
(
=4g
)
Confirm
card in the new slot
and
Delete
it from the old slot. The configuration data at the old slot location is now
deleted.
6. 3. 4
System modules
The category system modules comprises the modules expandable as an option (DSP
modules) and the mandatory RAM module.
6. 3. 4. 1
Changing the DSP module
The following describes how to replace a DSP module if it is defective or how to re-
place it for another module type.
To change a DSP module, proceed as follows:
1. Carry out preparations (see "Preparations", page 186).
2. Remove the housing cover.
3. Remove the old or defective module by loosening the fastening screw and carefully
pulling the module out vertically of the module slot.
TIC-2TS
→
TIC-4TS
The configuration data of terminal interfaces 3 and 4 are created as new.
TIC-2AB
→
TIC-4AB
The configuration data of network interfaces 3 and 4 are created as new.
CAUTION
!
Be sure to observe the "Safety regulations", page 89.