Operation and Maintenance
203
Mitel SMB Controller
syd-0657/2.0 – R6.0 – 09.2018
6. 4. 4. 3
Carry out a first start of MiVoice Office 400
The following sequence carries out a first start of MiVoice Office 400 application.
Note:
A first start deletes all the configuration data already stored and replaces it with the default val-
ues of the sales channel. Therefore, always back up the configuration data before a first start.
The system-specific data such as the system ID, system type, sales channel, software genera-
tion and IP address of the system are preserved.
1. Restart the SMB Controller with the
Restart
button in the SMB Controller Manager
System reset
view.
→
All applications are closed and the SMB Controller starts up again
OR
Shut-down the SMB Controller with a long click (> 5s) of the pilot key (CTRL)
→
All applications are closed and SMB Controller changes into the shut-down mode
and stays there for 1.5 minutes before it starts up again.
2. Press the pilot key (CTRL) while F0 lights up green during start up (pattern [11]).
→
As confirmation the F0 - F6 LED are rapidly flashing green 4 times (pattern [12]).
→
The first start is carried out.
→
The SMB Controller loads the system software and runs in normal mode.
→
The SMB Controller loads the MiVoice Office 400 application and a few seconds
later you are able to reach the MiVoice Office 400 communication server showing
the WebAdmin first access view.
Tab. 88
Carrying out a first start and reset sales channel
No.
PWR
F0
F1
F2
F3
F4
F5
F6
SYS
Dura-
tion
Meaning
[21]
~11s
Power is on, begin of restart
[22]
~2s
Do not touch pilot key
[23]
~2s
Press pilot key to carry out a
first start and reset sales chan-
nel
[24]
~2s
Confirmation
[25]
~50
Loading SMB Controller sys-
tem software
[26]
Normal mode, SMB Controller
is up and running
G
–
–
–
–
–
–
–
–
G
R
–
–
–
–
–
–
–
G
G
–
–
–
–
–
–
–
G
–
–
G G
–
–
G G
–
–
G G
–
–
G G
–
–
G G
–
–
G G
–
–
G G
–
G
–
–
–
–
–
–
–
–
G
–
–
–
–
–
–
–
–
G