(2) CWSoftLimitPoint_<Data>
Command to set CW side Software Limit of each axis.
Setting data is -99999999~99999999、-9.9999999~9.9999999.
*In case of continuing 0 after the decimal point., can be skippable.(Ex.:1.2300000=1.23)
*In case of data is not a multiple of the travel distance per pulse, corrects it as shown below.
1)Multiple=Data/Travel distance per pulse
2)Omit the figures after the decimal point of Multiple
3)Data=Travel distance per pulse×Multiple
(Travel distance per pulse=Standard resolution of motorized stage÷Dividing number of driver)
(3) CCWSoftLimitEnable_<Data>
This is setting command of soft limit effective/no effect CCW side for each axis.
<Data>
Content
0
Disable CCW Software Limit
1
Enable CCW Software Limit
(4) CCWSoftLimitPoint_<Data>
Command to set CCW side Software Limit of each axis.
Setting data is -99999999~99999999、-9.9999999~9.9999999.
*In case of continuing 0 after the decimal point., can be skippable.(Ex.:1.2300000=1.23)
*In case of data is not a multiple of the travel distance per pulse, corrects it as shown below.
1)Multiple=Data/Travel distance per pulse
2)Omit the figures after the decimal point of Multiple
3)Data=Travel distance per pulse×Multiple
(Travel distance per pulse=Standard resolution of motorized stage÷Dividing number of driver)
(5) DRiverDIVision_<Data>
Command to set a dividing number of drivers of each axis.
<Data>
<Number of Division/Steps>
0
1/1
1
1/2
2
1/2.5
3
1/4
4
1/5
5
1/8
6
1/10
7
1/20
8
1/25
9
1/40
10
1/50
11
1/80
12
1/100
13
1/125
14
1/200
15
1/250
※
<Data> has only 0, 1 when the normal driver.
※
When a display unit is except a pulse, if the number of driver division is changed, the travel
distance per pulse will change, and there is a case where the following parameters are no
longer a multiple of travel distance per pulse.