Calibration
Loading Default Calibration Values
NOTE: In metric, the width will have a decimal point, in
English there is no decimal point. Also, changing from
En glish to Met ric mode may change or alter any previously
en tered cal i bra tion values. After switch ing mea sure ment
modes, con firm that all cal i bra tion val ues are correct.
Press to enter or exit
calibration mode.
Press to increase or
decrease values.
Red warning light will be
lit when in CAL.
WIDTH
CAL
FLOW
CAL
MIN
FLOW
ADJUST
RATE
TARGET
RATE
SPEED
CAL
INLINE
BYPASS
TEST
SPEED
VOLUME /
MINUTE
DISTANCE
AREA /
HOUR
VOLUME
(1) (2) (3)
RATE
SPEED
AREA
(1) (2) (3)
ON
OFF
1
2
3
4
5
CONTROLLER 1 B O O M S
ON
OFF
CAL
CONT
SEL
RESET
MANAUTO
CALHOLD
V 1 2 3 4 5
CONTROLLER 1
APPLICATION RATE 2
TANK
___
CONTROLLER 2
APPLICATION RATE 1
AUTO
MAN
OFF
AUTO
MAN
MASTER
HOLD
English or Metric?
The MT-3405D is capable of displaying in for ma tion in Amer i-
can En glish or standard Metric measurement. The MT-3405D
is shipped from the factory programmed for English. Note
that the following procedures will also load factory default
calibration values. To simply change units without loading
defaults,
see the “Special Calibration” section.
METRIC
• You must be in MASTER HOLD or have all booms OFF
(on both channels) to enter Cal. To activate the Metric
mode, turn power OFF and place the ro ta ry switch at
“AREA.” Hold down both the “CAL” and “-” keys and turn
power ON. See Il lus tra tion to the right. The con sole will
display LOAd. Once LOAd is displayed, release the two
keys. To “lock-in” Metric mode you must enter and exit
cal i bra tion. Press and hold the CAL key until “CAL” icon
appears on the display. The con sole is now in cal i bra tion
and Metric mode is selected. Exit CAL by pressing and
holding the “CAL” key until CAL disappears from the
display (ap prox i mate ly 1 second).
NOTE: You must exit
CAL to lock in Metric units.
ENGLISH
• You must be in HOLD or have all booms OFF to enter
Cal. To activate the English mode, turn power OFF and
place the ro ta ry switch in the VOLUME position. Hold
down both the “CAL” and “-” keys and turn power ON.
The con sole will display LOAd. Once LOAd is displayed,
release the two keys. To “lock-in” English mode you
must enter and exit cal i bra tion. Press and hold the CAL
key until “CAL” lights on the display. The console is now
in cal i bra tion and English mode is selected. Exit CAL by
pressing and holding the “CAL” key until CAL disappears
from the display (approximately 1 second).
NOTE: You
must exit CAL to lock in English units.
Entering Calibration Values
To enter or change any of the system’s calibration values,
you must enter calibration mode. To enter calibration mode,
STOP the vehicle, turn all booms OFF or put the console in
HOLD and press and hold the CAL button until the “CAL” icon
appears (approximately one second).
(NOTE: Calibration
may be entered while moving, but it is not rec om mend ed
to attempt calibration while the vehicle is mov ing.)
The
console will remain in calibration mode, with the RED warning
light illuminated until you exit calibration or turn power OFF.
Once in calibration mode, you may change any one, all,
or none of the values, in any order.* To select a calibration
position, simply turn the rotary selector to the desired po si-
tion. Calibration positions are identified by the WHITE labeling
outside of the rotary selector. All values are entered and
adjusted using the “+” and “-” but tons on the left side of the
front panel.
NOTE: Tria/- buttons are ignored.
*TEST SPEED MUST BE LAST.
Hold the “CAL” key again for 1 second to exit calibration.
“CAL” will disappear from the display.
NOTE: You must exit
CAL to save changes.