NH3500 Kit - P/N 01101
The Liquifier
™
Kit P/N 01097
Main Harness - P/N 14366
E D
C
B
A
E
D
C
B
A
15’ 10-Pin M/P Extension Cable - P/N 13222
C
h
2
The Ch2 10-pin connector on the back panel of the
MT-3405D is designed to plug right into the harness P/N
13273 that is included in the NH3 kit. All that is needed is a
10-pin M/P extension cable of the appropriate length.
See
Appendix J for details.
C
h
1
An NH3 system can be connected to Channel 1 using the
NH3 Main Harness (P/N 14366) shown below. The 10-pin
connector at the other end of this harness plugs into the
standard NH3 harness (P/N 13273) that is included in the
NH3 kit. Choose an appropriate length extension cable
(for example, P/N 13222 shown below).
See Appendix J for
various extension lengths.
60
Appendix F
(cont)
MT-3405D - NH3 Specific
(cont)
Component Parts for MT-3405D for NH3 Kits
NH3500 Kit Installation
Remove any existing metering valves. If the old metering
valve has a built-in manifold, it is recommended to install
a separate new manifold for the NH3500 kit. Another
option, although not recommended, is to use the existing
manifold, making certain the old metering valve is in the
maximum open position to allow for minimal restriction of
flow through the plumbing. There also should not be any
positive shut-off valves installed in the plumbing between
the NH3500 kit shut-off valve and the knives.
Locate a convenient area on the applicator to install the
NH3500 plumbing panel. When selecting an installation
location, keep in mind that the hose from the break-away
coupler must reach the strainer inlet with enough length
to allow for proper operation of the break-away coupler
disconnect mechanism and prevent kinking of the hose at
hinge points. Also, the strainer’s clean-out plug should be
accessible for regular cleaning. Make certain that the area
selected allows for enough length of the manifold hose,
between the manifold and the servo valve outlet, to prevent
kinking at hinge points.
INSTALLATION NOTE:
It is recommended to use an NH3
compatible thread sealing compound such as “Slic-tite paste
with Teflon”, or a similar compound, on all pipe thread
fittings. Slic-tite is manufactured by LA-CO Industries, Inc./
Markal Company.
Remove the NH3500 plumbing panel from the shipping board.
Install the plumbing panel on the tool bar frame using the
bottom brackets, carriage bolts and flange lock nuts. Trim any
excess length off of the bolts if required. Attach the hose from
the break-away coupler to the strainer inlet. Check hose length
for proper operation of the break-away coupler disconnect
mechanism. Next, connect the manifold hose to the servo
valve outlet. Check for proper hose length to avoid kinking
at hinge points.
The Liquifier
™
MAX Kit
Содержание DUAL CONTROL MT-3405D
Страница 1: ...REFERENCE MANUAL DUAL CONTROL AUTOMATIC RATE CONTROLLER MT 3405D ...
Страница 47: ...Appendices 47 ...
Страница 56: ...P N 14366 56 Appendix F cont MT 3405D NH3 Specific cont MT 3405D Wiring Diagram for NH3 Channel 1 ...
Страница 82: ...82 NOTES ...
Страница 83: ......