Use
CONT SEL
button to view either Ch1 or Ch2 data.
(See the NH3 section in the Appendix (F) for NH3 data
description.)
RATE:
Actual number of gallons per acre (liters per hectare)
being applied.
TANK:
Amount (gal or lit) remaining in tank.
VOLUME/MINUTE:
Flow rate in GPM (LPM).
Three independent pairs of counters.
In either the AREA or the VOLUME
position, select a pair of counters by
pressing the “+” button. The active pair of counters (1,2,3) is
indicated by the small numbers in the lower right corner of
the left-hand display. DO NOT attempt to select the counter
pair by using the “-” button because it will reset the selected
counter pair to zero.
See additional data description to the
right and see RESETTING SYSTEM COUNTERS section.
VOLUME (1) (2) (3):
AREA (1) (2) (3):
)
Operation
(cont)
Data Displayed in Rotary Switch Positions
36
VOLUME (1) (2) (3):
Total gallons (liters) applied since the
active counter was last reset to zero.
AREA (1) (2) (3):
The acres (hectares) covered since the
counter was last reset to zero. The area counters do not
accumulate area when the console is in HOLD or if all booms
are turned OFF.
DISTANCE:
The feet (meters) driven since the counter was
last reset to zero. This counter does not accumulate when
the console is in HOLD. This counter may be reset to zero
independent of other system counters.
AREA/HOUR:
Rate of coverage in acres/hour (hectare/
hour).
SPEED:
Ground speed in miles (kilometers) per hour.
IMPORTANT: all booms automatically shut off if system is in
“HOLD” or if in AUTO with NO SPEED.
After the “-” (RESET) button has been held for 1 second, the
“CLEAr” message will be replaced by “.0”, indicating that
counter pair #3 has been cleared.
Note: Both Ch1 and Ch2 have their own (3) independent
sets of counters.
Clearing System Counters
When the desired counter number is displayed, press the
“-” (RESET) button and “CLEAr” will be displayed. If the
“-” button is released before 1 second has elapsed, the
counters will not be cleared and the “CLEAr” message will
be replaced with the previous total.
NOTE: holding the “-” (RESET) button for 1 second will
clear both the #3 AREA counter and the #3 VOLUME
counter whether the rotary switch is in the AREA or the
VOLUME position.
HOLD
3
WIDTH
CAL
FLOW
CAL
MIN
FLOW
ADJUST
RATE
TARGET
RATE
SPEED
CAL
INLINE
BYPASS
TEST
SPEED
VOLUME /
MINUTE
DISTANCE
AREA /
HOUR
VOLUME
(1) (2) (3)
RATE
SPEED
AREA
(1) (2) (3)
ON
OFF
1
2
3
4
5
CONTROLLER 1 B O O M S
ON
OFF
CAL
CONT
SEL
RESET
CONTROLLER 1
APPLICATION RATE 2
TANK
___
CONTROLLER 2
APPLICATION RATE 1
AUTO
MAN
OFF
AUTO
MAN
MASTER
HOLD
HOLD
V
3