63
PROVENO E
Rev. 1.2 (24.08.2016)
Adjustment instructions
6.2. Customer
specifi c parameters, settings and factory presets
The following table contains the parameter values starting from program revision 2r01. The program revi-
sion is visible on the temperature display a short moment after switching the kettle on.
Pr code Function
Display
Value
Factory pre-
set
Pr10
Default cooking temperature
Temperature
Timing
hPt
0 - 120
80
Pr11
Used temperature unit
Temperature
hEC
hEF
Celsius
Fahrenheit
hEC
Pr12
Default Hold temperature automatically set
after the cooking process
Temperature
Timing
hold
51 - 100
70
Pr13
Central dial selection delay (sec.) after which
the selected value is locked
Temperature
td_2 - td_7
td_5
Pr14
Low-temperature area (51-69°C heating
temperature difference
Temperature
hd 0 - hd30
Hd10
Pr15
Mid-temperature area (70-87°C) heating
temperature difference
Temperature
nd 0 - nd30
87°C temperature
fi xed 100°C
nd30
Pr16
Cooking temperature area 88-100°C)
heating temperature difference
Temperature
Hd 0 - Hd13
Hd13
Pr20
Selection and deselection of the short pull
back of the tilting done after releasing the
tilting
Temperature
Fbon
FboF
Pull back ON
Pull back OFF
Fbon
Pr21
Selection and deselection of the buzzer sig-
nal used when pausing and ending the mixer
Temperature
Mixer
AL
on
oFF
Buzzer ON
Buzzer OFF
on
Pr22
Forced slow mixing when tilting
Temperature
Mixer
FC15
on/off
off
Pr23
PIN code (only EaryRun 99.9 programming)
Temperature
Water fi ll
Info
PIn
Set/Old
_ _ _ _
_ _ _ _
Pr24
PCo cooling mixer speed
Temperature
Mixer
PCoS
15-50
25
Pr30
Water bypass time (min.) of the automatic
water fi lling system. Used to empty long
water supply lines of possibly musty water.
Temperature
Water fi ll
Fti
0 - 10
0 = no bypass
fl ow done
1
Pr31
Water bypass interval (hours) of the automa-
tic water fi lling system. When the interval
has elapsed a new bypass fl ow is done.
Temperature
Water fi ll
Fdi
0 - 24
0 = bypass fl ow
always done
12
Pr32
Automatic water fi lling unit selection
Water fi ll
Lit/GAL
Att!
Pr01
Lit
Pr33
Pure function behaviour in EasyRun pro-
gramming
Temperature
Water fi ll
FEr
OFF
Pr31
On
OFF=Pure never done
Pr31=Pure done ac-
cording to Pr31 setting
On=Pure always done
OFF
Pr40
Default cooling fi nal
Temperature
Info
CFt
0 - 100
30
Pr41
C5 cooling temperature setpoint when tap
water cooling is changed to Ice Bank
Temperature
Info
C2C3
0-100
0=C2
100=C3
75