4.2.14. EasyRun 1.1 programming
EasyRun programming consists of 4 different programs,
Er1
a single step cooking program
Er2
a two step program where the steps can be either cooking – cooling or cooling cooking
Er3
a three step program where each step can be either a cooking or cooling
step
ClnP
an automatic cleaning aid program with preset kettle size dependent settings
In an Er program
cooking step
the following functions can be set,
• the cooking temperature
• HACCP on or off (selection applies to the whole program)
• EasyRun stirring on or off
• use CheckPoint yes or no
• starting time of the fi rst step
• duration of the step
• amount of water to be fi lled
In an Er program
cooling step
the following functions can be set,
• the cooling temperature
• HACCP on or off (selection applies to the whole program)
• Cool stirring on or off
• use CheckPoint yes or no
• duration of the step
A cooking step is changed into a cooling step by pressing
for about 2 seconds.
A cooling step is changed into a cooking step by pressing
for about 2 seconds.
An Er program can be set to start at a maximum after seven days by setting the start time weekday and time.
If the fi rst step is a cooling step the start time must be more than the jacket drain time from the actual
time. The jacket drain time is 4 - 18 minutes depending of the kettle size. If the time between the actual
time and the starting time is shorter than the drain time the cooling step is ignored.
Setting a CheckPoint (CP) in a program step pauses the program until the user confi rms continuation of
the program, extends the step duration or lowers the cooling temperature in a co oling step.
The following functions are possible when an EasyRun program is in operation:
power mixing
interrupting the mixing function
changing the step duration
stopping with the emergency/stop button.