NATURAL GAS TO LPG CONVERSION
WARNING
This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s
instructions and all applicable codes and requirements of the authority having jurisdiction. If the information
in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result
causing property damage, personal injury or loss of life. The qualified service agency is responsible for the
proper installation of this kit. The installation is not proper and complete until the operation of the
converted appliance is checked as specified in the owner instructions supplied with the kit.
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts
specifically approved with this appliance may result in property damage or personal injury.
General Conversion Information
Kit # HA-88-00080 for Mendota Model FV46
Caution: The electrical supply to the fireplace must be turned
off prior to performing the conversion. The gas supply must
be shut off prior to disconnecting the electrical power.
Orifice sizes requirement
A Natural Gas to LPG conversion kit #HA-88-00080 must be ordered and
installed to convert the FV-46 Fireplace to burn LPG.
LP Conversion Kit #HA-88-00080 contains the following parts: One
Motorized LP Pressure Regulator and two Cap Orifices drill #55 and drill
#1/16th.
Figure 4-9 HA-88-00080 LP Kit Parts
Burner Orifices
[#55]
Motorized
LP Pressure
Regulator
[10.0-5.5"WC]
Burner Orifices
[#
1
16
th]
Содержание FV46
Страница 2: ...85 03 01108 FV46 P a g e 2 HOMEOWNER NOTES...
Страница 16: ...85 03 01108 C FV46 Page 16 Figure 3 9 Figure 3 8...
Страница 95: ......
Страница 96: ...Johnson Gas Appliance Company 520 E Avenue NW Cedar Rapids Iowa 52405 Mendota Warranty Registration...