85-03-01108-C
FV46
Page
17
FV46 Fireplace Ratings Information
This Mendota Fireplace can be installed directly on top of a metal, masonry or wood structural surface.
ELECTRICAL REQUIREMENTS
: 120 Volts AC, 1.5 Amps (minimum line voltage allowed 110 Volts AC) REQUIRED
GAS SUPPLY PRESSURE
: NAT. GAS: 7" W.C. [5.0" W.C. MIN., 11" W.C. MAX.]
L.P. GAS: 11" W.C. [11" W.C. MIN., 13" W.C. MAX.]
LP GAS CONVERSION KIT
: This Fireplace comes configured for use with Natural Gas. To convert the Fireplace for use with LP
Gas, install: LP GAS CONVERSION KIT #HA-88-00080.
GAS INPUT RATES
High Fire
Low Fire
BTUH .......................... NAT. GAS
45,500
13,450
BTUH .......................... L.P. GAS
45,500
15,840
ORIFICE SIZES
………… [0-2000ft (610 m)]: REAR BURNER: #37 NG 1/16” L.P.] – FRONT BURNER: #44 NG [#55 LP]
[2000-4500ft (610-1370 m)]: REAR BURNER: #37 NG 1/16” L.P.] – FRONT BURNER: #44 NG [#56 LP]
P.4 FIREPLACE EFFICIENCY ..........71.92%
FLUE VENTING
............COAXIAL RIGID- 5” DIAMETER EXHAUST & 8” DIAMETER AIR INLET AND APPROVED VENT CAPS
All UL Listed Coaxial Rigid 5”X8” Vent pipe components and vent caps are approved for use. Do not mix components of different
brands or series. Always use the same brand and series components throughout the entire vent system.
MINIMUM CLEARANCES TO COMBUSTIBLE CONSTRUCTION
UNIT TO FLOOR
0in. (0 mm)
GLASS FRAME EDGE TO ADJACENT SIDEWALL 16in. (406 mm)
UNIT TO ENCLOSURE SIDEWALL
1/2in. (13 mm) VENT PIPE TOP TO COMBUSTIBLES
3in. (76 mm)
UNIT TO ENCLOSURE BACK WALL
1/2in. (13mm) VENT PIPE SIDES TO COMBUSTIBLES
1in. (25 mm)
UNIT BOTTOM TO ENCLOSURE CEILING 55 in. (127 cm) VENT PIPE BOTTOM TO COMBUSTIBLES 1in. (25 mm)
UNIT BOTTOM TO ROOM CEILING
72 in. (1829 mm)
DISTANCE TO 8” MANTLE FLOOR LEVEL 54 in. (1370 mm)
MINIMUM COMBUSTIBLE ROUGH FRAMING DIMENSIONS
ENCLOSURE WIDTH = 51” (130cm)
FINISHED FRAMING WIDTH = 45” (114cm)
HEIGHT = 48 1/2” (123cm)
DEPTH= 22 1/2” (57cm)
NET WEIGHT
................325 lbs. (Team Lift recommended)
BARRIER SCREEN
: A barrier screen that has been certified for use with this Fireplace must be installed on the Fireplace when it
is in use. The barrier screen will prevent accidental contact with the glass door face, which could result in a severe burn.
SAFETY
: AGA certified, electronic ignition IPI system activated with thermostatic remote control.
CERTIFIED TO
: ANSI Z21.88-2017/ CSA2.33-2017
This Mendota Gas Fireplace has been tested and certified by:
Intertek Testing Services, 8431 Murphy Drive, Middleton, WI 53562\
ICBO#AA647-4