Rebuilding an Existing (Failed) 3ware RAID 5 Array
The discussions in this section assume that you originally have a good, working RAID 5 array. In this
case, if you double-click the
Connect to 3DM 2
icon on your desktop and login to the ensuing
webpage using the default password (which is
3ware
), you will see that the status of your array looks
something like that shown in Figure 2-35.
Figure 2-35
Once you have observed this good array, exit out of the 3DM 2 web interface. At some stage, one of
the disks in the array may start to degrade or go completely off-line. For the purposes of these
discussions, we are going to power down the system, physically remove Disk 01 from the array
(thereby simulating a catastrophic failure on this disk) and power up the system back up again.
1) Power down the system and remove the center data disk (Disk 01) as shown in Figure 2-36.
Figure 2-36
Figure 2-37
2) Power the system back up again. The BIOS detects the fact that there is a problem with the RAID
array and displays an appropriate message (Figure 2-37). Press the <Pause Break> key to freeze
the display; from this (and Figure 2-8) you will be able to determine which drive has failed.
3) Press and hold the soft power key in order to power the system down.