7.2 The reason and handling of alarm
207
Err24 (Under voltage of control power supply)
Potential cause
Check
Handle
Control circuit LDO fault
Check the power of
control board
Replace the servo driver.
Err27 (Phase loss alarm)
Potential cause
Check
Handle
Phase loss of power supply
Check the wiring of
L1, L2,L3
Connect wire correctly
Power supply undervoltage
Check supply power
voltage
Ensure correct voltage input
Phase loss checking return circuit
error
Check optocoupler,
power on again
If error still exists, please replace
drive
Err29 (Over-torque alarm)
Potential cause
Check
Handle
Unexpected big load occurs
Check
load
condition
Correctly readjust the load.
Parameter P070
、
P071
、
P072
setting is not reasonable
Check the
parameters
Correctly readjust parameters.
Err30 (Lost Z signal of encoder)
Potential cause
Check
Handle
Encoder has problem
Check the encoder Z
signal
Replace the encoder
Encoder cable and/or connector
has problem
Check cable and
connector
Replace the cable and connector.
The interface circuit of the servo
driver is at fault
Check the control
circuit
Replace the servo driver.
Содержание EP3 AC Series
Страница 1: ...Wuhan Maxsine Electric Co Ltd...
Страница 12: ...Chapter 1 Product inspection and installment 2 1 2 Product nameplate...
Страница 16: ...Chapter 1 Product inspection and installment 6...
Страница 39: ...2 5 Standard wiring diagram 29 2 5 Standard wiring diagram 2 5 1 Wiring diagram for position control...
Страница 40: ...Chapter 2 Wiring 30 2 5 2 Wiring diagram for speed or torque control...
Страница 56: ...Chapter 3 Front panel operation 46 6 Turn off and on the power supply then an operation can be performed again...
Страница 57: ...3 7 Resume the parameter default values 47 Remarks...
Страница 124: ...Chapter 4 Running 114 Remarks...
Страница 221: ...198 Chapter 8 Specifications 8 1 Types of servo driver...
Страница 231: ...8 5 Types of servo motor 8 5 Types of servo motor...
Страница 245: ...Edition antecedents Edition number Published time Modify content First edition Janunary 2013 Applies to software version...