Chapter 5 Parameters
172
P412
Path 7 control word low 16 bits
Range
Default
value
Unit
Usag
e
-32768
~
32767
0
M
Path 7 control word low 16 bits, refers to parameter P400 for explanation.
P413
Path 7 control word high 16 bits
Range
Default
value
Unit
Usag
e
-32768
~
32767
0
M
Path 7 control word high 16 bits, refers to parameter P401 for explanation.
P414
Path 8 control word low 16 bits
Range
Default
value
Unit
Usag
e
-32768
~
32767
0
M
Path 8 control word low 16 bits, refers to parameter P400 for explanation.
P415
Path 8 control word high 16 bits
Range
Default
value
Unit
Usag
e
-32768
~
32767
0
M
Path 8 control word high 16 bits, refers to parameter P401 for explanation.
5.4.6 Parameters of section 5
P500
Path 1 data low 16 bits
Range
Default
value
Unit
Usag
e
-32768
~
32767
0
PUU
M
This parameter is used in motion mode. When path TYPE is one and position command is
chose, this parameter means the low 16 bits of target position
Cooperate with the high 16 bits of path data to form the target position of 32 digit. The unit
is PUU, which is equal to the resolution of encoder.
The target position is confirmed related to the position after origin regression. Regard the
position after origin regression as origin
P501
Path 1 data high 16 bits
Range
Default
value
Unit
Usag
e
-32768
~
32767
0
PUU
M
This parameter is used in motion mode. When the path TYRE is 1 and position command is
chose, this parameter means the high 16 bits of target position.
Cooperate with the low 16 bits of path data to form the target position of 32 bits. The unit is
PUU, which is equal to the resolution of encoder.
Содержание EP3 AC Series
Страница 1: ...Wuhan Maxsine Electric Co Ltd...
Страница 12: ...Chapter 1 Product inspection and installment 2 1 2 Product nameplate...
Страница 16: ...Chapter 1 Product inspection and installment 6...
Страница 39: ...2 5 Standard wiring diagram 29 2 5 Standard wiring diagram 2 5 1 Wiring diagram for position control...
Страница 40: ...Chapter 2 Wiring 30 2 5 2 Wiring diagram for speed or torque control...
Страница 56: ...Chapter 3 Front panel operation 46 6 Turn off and on the power supply then an operation can be performed again...
Страница 57: ...3 7 Resume the parameter default values 47 Remarks...
Страница 124: ...Chapter 4 Running 114 Remarks...
Страница 221: ...198 Chapter 8 Specifications 8 1 Types of servo driver...
Страница 231: ...8 5 Types of servo motor 8 5 Types of servo motor...
Страница 245: ...Edition antecedents Edition number Published time Modify content First edition Janunary 2013 Applies to software version...