Chapter 4 Running
96
4.9.5 Timing chart of homing for combination mode
For homing, the reference point mode (P179) and the origin mode (P180) cab be combined
and have the following combinations. The detailed actions of each combined mode refer to 4.9.3
section.
(A) P179=0 or 2/P180=0
Parameter
Setting
explanation
P179
0 or 2
After starts homing, seek REF (rising edge trigger) or CCWL
(falling edge trigger) in CCW direction with first speed (P183)
and take it the reference point.
P180
0
After found the reference point, seek Z pulse in backward
direction with second speed (P184) and take it the origin.