Chapter 5 Parameters
152
P146
Internal torque 2
Range
Default
value
Unit
Usag
e
-300
~
300
0
%
T
This is the internal torque 2. Refer to the explanation of parameter P026.
P147
Internal torque 3
Range
Default
value
Unit
Usag
e
-300
~
300
0
%
T
This is the internal torque 3. Refer to the explanation of parameter P026.
P148
4 Internal torque 4
Range
Default
value
Unit
Usag
e
-300
~
300
0
%
T
This is the internal torque 4. Refer to the explanation of parameter P026.
P150
Range for positioning completion
Range
Default
value
Unit
Usag
e
0
~
32767
10
pulse
P
Set the pulse range for positioning completion under the position control mode.
When the pulse number in the position deviation counter is smaller than or equal to this
setting value, the digital output DO COIN is ON (positioning completion), otherwise is
OFF.
The comparator has hysteretic function set by parameter P151.
P151
Hysteresis for positioning
completion
Range
Default
value
Unit
Usag
e
0
~
32767
5
pulse
P
Refer to the explanation of parameter P150.
P152
Range for approach positioning
Range
Default
value
Unit
Usag
e
0
~
32767
500
pulse
P
Set the pulse range for approach positioning under the position control mode.
When the pulse number in the position deviation counter is smaller than or equal to this
setting value, the digital output DO NEAR is ON (near position), otherwise is OFF.
The comparator has hysteretic function set by parameter P153.
Use this function in case that in near positioning, the host controller is accepting the NEAR
signal to carry on the preparation to the next step. In general, the parameter value must be
bigger than P150.
Содержание EP3 AC Series
Страница 1: ...Wuhan Maxsine Electric Co Ltd...
Страница 12: ...Chapter 1 Product inspection and installment 2 1 2 Product nameplate...
Страница 16: ...Chapter 1 Product inspection and installment 6...
Страница 39: ...2 5 Standard wiring diagram 29 2 5 Standard wiring diagram 2 5 1 Wiring diagram for position control...
Страница 40: ...Chapter 2 Wiring 30 2 5 2 Wiring diagram for speed or torque control...
Страница 56: ...Chapter 3 Front panel operation 46 6 Turn off and on the power supply then an operation can be performed again...
Страница 57: ...3 7 Resume the parameter default values 47 Remarks...
Страница 124: ...Chapter 4 Running 114 Remarks...
Страница 221: ...198 Chapter 8 Specifications 8 1 Types of servo driver...
Страница 231: ...8 5 Types of servo motor 8 5 Types of servo motor...
Страница 245: ...Edition antecedents Edition number Published time Modify content First edition Janunary 2013 Applies to software version...