5.4 Parameter description in detail
143
speed adjustment, the demonstration mode).
The torque limitation is not related to the rotation direction. It is valid in both directions.
The internal and the external torque limitation are still effective.
P070
Alarm level of torque overload in
CCW direction
Range
Default
value
Unit
Usag
e
0
~
300
300
%
ALL
Set the overload value of torque in (CCW) direction. This value indicates the percentage of
rated torque.
When the torque of the servomotor surpasses P070 and the duration is bigger than P072,
then the servo driver alarms, and the servomotor stops. The number of the alarm is Err29.
P071
Alarm level of torque overload in
CW direction
Range
Default
value
Unit
Usag
e
-300
~
0
-300
%
ALL
Set the overload value of torque in (CW) direction. This value indicates the percentage of
rated torque.
When the torque of the servomotor surpasses P070 and the duration is bigger than P072,
then the servo driver alarms, and the servomotor stops. The number of the alarm is Err29.
P072
Detection time for torque overload
alarm
Range
Default
value
Unit
Usag
e
0
~
10000
0
10ms
ALL
Refer to the explanation of parameter P070 and P071.
The torque overload can be shielded if the setting value is zero.
P075
Maximum speed limit
Range
Default
value
Unit
Usag
e
0
~
6000
3500
r/min
ALL
Set the permission highest speed of servomotor.
The limit is effective in both CCW and CW direction.
If the setting value surpasses the system permission the maximum speed, the actual speed
also can limit in the maximum speed.
P076
JOG running speed
Range
Default
value
Unit
Usag
e
0
~
5000
100
r/min
S
Set the running speed for JOG operation.
P077
Selection of speed limit
Range
Default
value
Unit
Usag
e
0
~
2
0
T
Set the speed limitation mode for torque control. The speed limitation is effective in both
CCW and CW direction.
Содержание EP3 AC Series
Страница 1: ...Wuhan Maxsine Electric Co Ltd...
Страница 12: ...Chapter 1 Product inspection and installment 2 1 2 Product nameplate...
Страница 16: ...Chapter 1 Product inspection and installment 6...
Страница 39: ...2 5 Standard wiring diagram 29 2 5 Standard wiring diagram 2 5 1 Wiring diagram for position control...
Страница 40: ...Chapter 2 Wiring 30 2 5 2 Wiring diagram for speed or torque control...
Страница 56: ...Chapter 3 Front panel operation 46 6 Turn off and on the power supply then an operation can be performed again...
Страница 57: ...3 7 Resume the parameter default values 47 Remarks...
Страница 124: ...Chapter 4 Running 114 Remarks...
Страница 221: ...198 Chapter 8 Specifications 8 1 Types of servo driver...
Страница 231: ...8 5 Types of servo motor 8 5 Types of servo motor...
Страница 245: ...Edition antecedents Edition number Published time Modify content First edition Janunary 2013 Applies to software version...