Chapter 5 Parameters
136
3. The command frequency is lower;
4. When the servomotor is in motion appears step-by-steps or unstable phenomenon.
P046
Gain of analog speed command
Range
Default
value
Unit
Usag
e
10
~
3000
300
r/min/V
S
This proportional coefficient is that the servomotor actual speed divides by the analog input
voltage.
The analog input voltage is in the range from -10V to 10V.
P047
Zero offset compensation of analog
speed command
Range
Default
value
Unit
Usag
e
-1500.0
~
1500.0
0.0
mv
S
This is the zero-bias compensation for analog speed input. The actual speed command is
that the analog speed input minus this parameter value.
By using the analog zero-bias auto-setting function this parameter is set automatically.
Refer to 3.6.2 section.
Содержание EP3 AC Series
Страница 1: ...Wuhan Maxsine Electric Co Ltd...
Страница 12: ...Chapter 1 Product inspection and installment 2 1 2 Product nameplate...
Страница 16: ...Chapter 1 Product inspection and installment 6...
Страница 39: ...2 5 Standard wiring diagram 29 2 5 Standard wiring diagram 2 5 1 Wiring diagram for position control...
Страница 40: ...Chapter 2 Wiring 30 2 5 2 Wiring diagram for speed or torque control...
Страница 56: ...Chapter 3 Front panel operation 46 6 Turn off and on the power supply then an operation can be performed again...
Страница 57: ...3 7 Resume the parameter default values 47 Remarks...
Страница 124: ...Chapter 4 Running 114 Remarks...
Страница 221: ...198 Chapter 8 Specifications 8 1 Types of servo driver...
Страница 231: ...8 5 Types of servo motor 8 5 Types of servo motor...
Страница 245: ...Edition antecedents Edition number Published time Modify content First edition Janunary 2013 Applies to software version...