5.4 Parameter description in detail
149
This is the time-constant of DI5 input digital filter. Refer to the explanation of parameter
P110.
P120
Forced effect in DI digital inputs
(group 1)
Range
Default
value
Unit
Usag
e
00000
~
11111
00000
ALL
T
he function corresponding to 5 binary bit is as following:
Bit number
bit4
Bit3
Bit2
Bit1
bit0
Function CWL CCWL
ARST
SON
NULL
Use in forcing the DI input function to be effective. If the corresponding bit of function is
set, then this function forces ON (effectively).
The meaning of DI symbol string refers to 5.5 sections.
The meanings of this parameter are:
Certain bit of this
parameter
Function[note]
Function result
0 Not
yet
planned
OFF
Has planned
Determine by input
signal
1
Not yet planned or
has planned
ON
Note: 'Has planned' indicates the function which is selected by parameter P100~P104.
'Not yet planned' indicates the function which is not selected by parameter P100~P104.
P121
Forced effect in DI digital inputs
(group 2)
Range
Default
value
Unit
Usag
e
00000
~
11111
00000
ALL
The function corresponding to 5 binary bit is as following:
Bit number
bit4
bit3
bit2
bit1
bit0
Function CINV
CZERO
ZCLAMP
TCW
TCCW
Refer to the explanation of parameter P120 for others.
P122
Forced effect in DI digital inputs
(group 3)
Range
Default
value
Unit
Usag
e
00000
~
11111
00000
ALL
T
he function corresponding to 5 binary bit is as following:
Bit number
bit4
bit3
bit2
bit1
bit0
Function TRQ2
TRQ1 SP3 SP2 SP1
Refer to the explanation of parameter P120 for others.
P123
Forced effect in DI digital inputs
(group 4)
Range
Default
value
Unit
Usag
e
00000
~
11111
00000
ALL
The function corresponding to 5 binary bit is as following:
Содержание EP3 AC Series
Страница 1: ...Wuhan Maxsine Electric Co Ltd...
Страница 12: ...Chapter 1 Product inspection and installment 2 1 2 Product nameplate...
Страница 16: ...Chapter 1 Product inspection and installment 6...
Страница 39: ...2 5 Standard wiring diagram 29 2 5 Standard wiring diagram 2 5 1 Wiring diagram for position control...
Страница 40: ...Chapter 2 Wiring 30 2 5 2 Wiring diagram for speed or torque control...
Страница 56: ...Chapter 3 Front panel operation 46 6 Turn off and on the power supply then an operation can be performed again...
Страница 57: ...3 7 Resume the parameter default values 47 Remarks...
Страница 124: ...Chapter 4 Running 114 Remarks...
Страница 221: ...198 Chapter 8 Specifications 8 1 Types of servo driver...
Страница 231: ...8 5 Types of servo motor 8 5 Types of servo motor...
Страница 245: ...Edition antecedents Edition number Published time Modify content First edition Janunary 2013 Applies to software version...