Chapter 4 Running
108
by TRQ1 and TRQ2 from DI inputs.
Note: 1.The final limitation value will be the smallest value if many limits occur.
2. The limit of the P065 and the P066 is effective all the time.
3. Even if the setting value greater than the permission maximum speed of the system,
but the operation also can limit in the maximum torque range.
The inner torque commands are:
DI Signals[Note]
Torque command
TRQ2 TRQ1
0
0
Internal torque 1 (parameter P145)
0
1
Internal torque 2 (parameter P1456)
1
0
Internal torque 3 (parameter P147)
1
1
Internal torque 4 (parameter P148)
Note: 0 indicates OFF, 1indicates ON.
Содержание EP3 AC Series
Страница 1: ...Wuhan Maxsine Electric Co Ltd...
Страница 12: ...Chapter 1 Product inspection and installment 2 1 2 Product nameplate...
Страница 16: ...Chapter 1 Product inspection and installment 6...
Страница 39: ...2 5 Standard wiring diagram 29 2 5 Standard wiring diagram 2 5 1 Wiring diagram for position control...
Страница 40: ...Chapter 2 Wiring 30 2 5 2 Wiring diagram for speed or torque control...
Страница 56: ...Chapter 3 Front panel operation 46 6 Turn off and on the power supply then an operation can be performed again...
Страница 57: ...3 7 Resume the parameter default values 47 Remarks...
Страница 124: ...Chapter 4 Running 114 Remarks...
Страница 221: ...198 Chapter 8 Specifications 8 1 Types of servo driver...
Страница 231: ...8 5 Types of servo motor 8 5 Types of servo motor...
Страница 245: ...Edition antecedents Edition number Published time Modify content First edition Janunary 2013 Applies to software version...