[Relationship between input analog signals and output values]
Pin 1: ACVCON signal: AC voltage/current
Input 0V: Output = rating x 0%
Input 10V: Output = rating x 105%
Pin 14: FCON signal: AC Frequency
Input 0V: Output = 1kHz
Input 10V: Output = 200kHz
Pin 15: DCVCON signal: CC voltage/current
Input 0V: Output = rating x 0%
Input 10V: Output = rating x 105%
The polarity is switched with the pin 17: DC_POLE signal.
When analog signals are input, the text of the currently enabled setting values will be displayed
in black.
Set each value while checking the displayed values.
Furthermore, analog signals linearly change as shown below.