5 Sequence Function
65
DOEF series
Matsusada Precision
5-4 Description of Sequence Screen
There are four screens below:
1. Sequence run/stop
2. Program edit
3. Step edit 1
4. Step edit 2
For example, in the case of the starting or stopping a sequence, use 1: Sequence run/stop screen.
The screen is also used to call a program.
The other 2 to 4 screens is used to edit the settings of sequence programs.
5-4-1 Sequence Run/Stop
SQC Run
Matsusada
Prog No.
Step
Time
Loop
Prog Edit
LOC
1
104
5.6 s
846
Vdc -15.980 V
Vrms 0.142 V
Irms 0.033 A
Idc -10.015 A
AC
CV
DC
Sequence
[Current status]
State of CV or CC mode, DC or ACDC mode,
remote or local mode, etc.
[Measurement]
[Sequence condition]
Run, Stop, or Pause
Current program number
Current step number
Elapsed time
[Current screen]