6 Master/Slave Option
89
DOEF series
Matsusada Precision
4. Measured value
In master/slave operation, the master unit displays the total value of master/slave operation in the
case of current measurement, and the slave unit displays its own value. About the voltage values,
each unit displays its measured value.
[Readout of measured values via communication]
When reading out measured values with the communication option, only the master unit is connected to a
controller via the communication and read out the total values across the entire master/slave units.
The slave units are not allowed to use communication function.
Irms 28.280 A
Idc +20.001 A
On the other hand, the current
values of the master unit display the
total values.
Matsusada
Vdc +10.006 V
Vrms 14.140 V
Measured values of the master unit
<
MASTER
>
Vdc +10.001 V
Vrms 14.140 V
Irms 14.140 A
Idc +10.003 A
Matsusada
Measured values of the slave unit
<
SLAVE
1>
The current values of a slave unit
display its measured values.