4 Operation
48
DOEF series
Matsusada Precision
4-2-5 Setting Values for Protection
[Setting of protection system for overvoltage and overcurrent]
Select one of the following.
Limit protection
Cutoff protection
[Setting of limit protection for overvoltage]
Positive:
Setting range: 0.1 to rating x 110%
Setting unit: 0.1 [V]
Negative:
Setting range:
−0.1 to –rating x 110%
Setting unit:
−0.1 [V]
[Setting of cutoff protection for overvoltage]
Setting range: 0.1 to rating x 110%
Setting unit: 0.1 [V]
[Setting of limit protection for overcurrent]
Positive:
Setting range: 0.1 to rating x 110%
Setting unit: 0.1 [A]
Negative:
Setting range:
−0.1 to –rating x 110%
Setting unit:
−0.1 [A]
[Setting of cutoff protection for overcurrent]
Setting range: 0.1 to rating x 110%
Setting unit: 0.1 [A]
[Setting of cutoff protection for sink power]
Setting range:
−1 to −300 [W] for 600W model
−1 to −600 [W] for 1200W model
Setting unit: 1 [W]