4 Operation
15
DOEF series
Matsusada Precision
4-1-2 OUTPUT ON/OFF
In order to turn the output ON or OFF, press the OUTPUT switch.
Pressing the OUTPUT switch while the output is off will turn the output ON and the OUTPUT LED will
be lit in red.
Also, pressing the OUTPUT switch while the output is on will turn the output OFF and the OUTPUT
LED will be unlit.
In addition, when between CV and CC mode, or DC and AC+DC mode is switched while the output is
ON, the unit will turn off the output for safety.
Moreover, it is not allowed to shift to sequence operation while the output is turned ON.
[If the LED is blinking]
LS function is enabled and the output is available at any time.
Short-circuiting the LS signal to common will turn the output ON.
When the LS function is not used, disable it.
[If FAULT is displayed after the output was turned ON]
A protection is activated and the unit is in a fault state.
Check the settings of the protection and the load.
OUTPUT LED
Lit in red: Output ON
Unlit:
Output OFF
OUTPUT switch
Содержание DOEF Series
Страница 1: ...Instruction Manual F RA 001 3R2 MODEL DOEF series B N 243 9 024 243 9 024 Rev 0 4 ...
Страница 15: ...2 External Appearance 7 DOEF series Matsusada Precision 2 3 Dimensions 2 3 1 400W Model ...
Страница 16: ...2 External Appearance 8 DOEF series Matsusada Precision 2 3 2 600W Model ...
Страница 17: ...2 External Appearance 9 DOEF series Matsusada Precision 2 3 3 1200W Model ...
Страница 121: ......
Страница 123: ......
Страница 124: ......