3-15
CD25
OPERATING CONTROLS AND PROCEDURES
3
Published 1-06-2017 Control # 579-01
4.
Place the travel select lever (Figure 3-22) in the neutral
(N) position.
NOTE: DO NOT
operate the engine at full RPM or apply a
full load until the engine is warm.
The diesel engine in this crane is equipped with an
air intake heating system. When starting the engine
in cold weather the
Engine Wait to Start Indicator
page 3-8 will illuminate. Do not attempt to start the
engine until this indicator goes out.
5.
Turn the ignition switch to the START position to crank
the engine. Release the switch when the engine starts.
Do not press the accelerator pedal, the engine ECM will
determine the proper idle speed.
If the engine fails to start on the first try, wait until the
starter motor comes to a complete stop; then again
crank the engine with the ignition key.
6.
Check the engine oil pressure warning light. See
Figure 3-5. If the warning light is illuminated, shut down
the engine immediately. Have the engine serviced
before placing the crane in service.
7.
Check the brakes, steering and all controls for proper
operation. If a malfunction is found, shut down the
engine immediately and park the crane until the
malfunction is corrected or the crane can be safely
towed (See
8.
Disengage the parking brake before you travel with the
crane. See
Towing or Pushing the Crane to Start the Engine
If the battery is discharged,
DO NOT
try to start the engine by
towing or pushing the crane. Damage to the transmission will
occur. Instead use booster batteries to jump start the engine.
Jump Starting the Engine
Follow the recommended jump starting procedure below
when using booster batteries to start the engine.
1.
Wear eye protection.
2.
Engage the parking brake.
3.
Place the travel select lever in the Neutral (N) position.
4.
Stop all electrical loads (lights, heaters, etc.)
5.
Lift the battery access cover and locate the battery
(Figure 3-23).
CAUTION
Do not bypass the crane’s neutral-start system. The
neutral start system must be repaired if it malfunctions.
DO NOT
crank the starter motor continuously for more
than 30 seconds. Damage to the starter motor could
occur.
FIGURE 3-21
FIGURE 3-22
Travel Select Lever
FIGURE 3-23
p0399
Battery Location
Reference Only
Содержание CD25
Страница 5: ...Operator Manual CD25 R e f e r e n c e O n l y ...
Страница 6: ...R e f e r e n c e O n l y ...
Страница 14: ...TABLE OF CONTENTS CD25 OPERATOR MANUAL TOC 6 THIS PAGE BLANK R e f e r e n c e O n l y ...
Страница 18: ...INTRODUCTION CD25 1 4 Published 1 06 2017 Control 579 01 THIS PAGE BLANK R e f e r e n c e O n l y ...
Страница 55: ...2 37 CD25 SAFETY INFORMATION 2 Published 1 06 2017 Control 579 01 8496 1 FIGURE 2 10 R e f e r e n c e O n l y ...
Страница 66: ...SAFETY INFORMATION CD25 2 48 Published 1 06 2017 Control 579 01 2 48 THIS PAGE BLANK R e f e r e n c e O n l y ...
Страница 100: ...CAPACITY CHART CD25 4 4 Published 1 06 2017 Control 579 01 THIS PAGE BLANK R e f e r e n c e O n l y ...
Страница 150: ...MAINTENANCE CD25 6 40 Published 1 06 2017 Control 579 01 THIS PAGE BLANK R e f e r e n c e O n l y ...
Страница 152: ...ADJUSTMENTS CD25 7 2 Published 1 06 2017 Control 579 01 THIS PAGE BLANK R e f e r e n c e O n l y ...
Страница 156: ...8 4 SPECIFICATIONS CD25 Published 1 06 2017 Control 579 01 Boom angle Maximum 80 Minimum 0 R e f e r e n c e O n l y ...
Страница 159: ...R e f e r e n c e O n l y ...
Страница 160: ...R e f e r e n c e O n l y ...