2014 Magnum Energy, Inc.
Page 115
Using a PT Controller: Operation/Monitoring
Figure 10-5, PT Charge Controller CTRL/METER Menu Map
CTRL
Set PT Aux Relay
Ctrl= DISENGAGE
04B PT Aux Relay
Ctrl= DISENGAGE
R
R
R
04 PT Control
Press SELECT
Charger Off
Start Float
Start Bulk
Start EQ (5sec)
R
R
P
P
04A PT CHG Ctrl
Multi-Stage
Set PT CHG Ctrl
Multi-Stage
EQ Charge Starts
in x.x seconds
EQ Charge Starts
EQ STARTED
P
Press and hold
SELECT button
for 5 seconds
PT Status
[PT Status]
P
R
R
Read Only displays
P
VDC,FAULT, ENGAGE
04C PT Alarm
Control= OFF
Set PT Alarm
Control= OFF
P
R
VDC,FAULT,ON
Set PT MPPT Ctrl
15 Min Sweep
P
R
5 Min Sweep
1 Hour Sweep
Fixed Sweep
04D PT MPPT Ctrl
15 Min Sweep
R
Power Status
[MPPT Status]
Relay Status
[AuxRelay Status]
07C Bat Volts-PT
14.4 VDC
R 07B PV Volts-PT
147.0 VDC
R
R
07D Target Volts
14.0 VDC / 100F
07E Bat Amps-PT
100.0 ADC
Absorb Charging
Float Charging
Int Overload-PT
ARC Fault-PT
Ground Fault-PT
Int Phase-PT
BTS Open-PT
HiBatt Temp-PT
Int Power-PT
BTS Shorted-PT
High Bat VDC-PT
Int Pwr Sup-PT
Bulk Charging
High PV VDC-PT
No PV Input-PT
Equalizing
Ind Overtemp-PT
Sleeping
FET Overtemp-PT
Int Hardware-PT
Unknown Fault ##
Int NTC-PT
UnknownStatus ##
Available Statuses:
Available Statuses:
Available Statuses:
Limit: Above VDC
Limit: Int Hz
Limit: Int Temp
MMPT On
No Power Out
Regulating: Amps
Regulating: VDC
Unknown Power ##
Disengage
Engage
METER button menus
continue on next page
07A PT Status
Press SELECT
METER
[Status/Fault]
07 PT Meters
P
10.2.3 PT Charge Controller Menu Maps
Figures 10-2 through 10-5 are a complete overview of the PT settings and information displays
available from the ME-ARC remote’s CTRL, METER, and SETUP menus.
Note:
When applicable, battery voltage defaults and ranges are shown for a 12-volt battery (24-
volt systems multiply by 2; 48-volt systems multiply by 4).