© 2015 Sensata Technologies
Setup
28
60 Minutes
AGM 1
Flooded
Battery
Type
Absorption
Voltage
Float
Voltage
Equalization
Voltage
Equalization
Time
Flooded
14.6 VDC
13.4 VDC
15.5 VDC
2.0 Hours
GEL
14.1 VDC
13.6 VDC
Not Allowed
Not Applicable
AGM 1
1
14.3 VDC
13.1 VDC
15.5 VDC
2.0 Hours
AGM 2
2
14.5 VDC
13.5 VDC
Not Allowed
Not Applicable
Table 3-1, Battery Type to Charge Voltages
Note
1
: Specifi cations for Concord (Lifeline Series) AGM batteries.
Note
2
: Specifi cations for East Penn, Deka, Discover and Trojan AGM batteries.
Info:
Voltages shown in Table 3-1 are based on the Battery
Temperature Sensor (BTS) being disconnected, or at a
temperature of 77°F (25°C). If the BTS is connected, the
charge voltage changes based on the temperature around
the BTS—to ensure the batteries receive the correct charge
voltage even if they become cold or hot (see Section 1.5.2).
GEL
AGM 2
Switches 8 & 9: Absorb Time
DIP Switches 8 & 9 determine the absorption charge time of the
MMSA inverter/charger. Four (4) time periods are provided to
determine how long the charger is in the Absorb Charge stage—
holding the batteries at the
Absorb Voltage
setting.
120 Minutes
90 Minutes
150 Minutes