![Lynx NGT-9000 Series Скачать руководство пользователя страница 99](http://html1.mh-extra.com/html/lynx/ngt-9000-series/ngt-9000-series_installation-manual_1953763099.webp)
Lynx NGT-9000
Installation Manual
3.7.2 I/O Options – AHRS and Altitude
From the Lynx MAT select Setup
Z
Configuration
Z
Modify
Z
I/O Options
Z
AHRS and Altitude.
See Figure 3-10. Enter the information specific to the installation for the intended certification.
Figure 3-10: Lynx MAT – I/O Options – AHRS and Altitude
1.
AHRS
a.
Source
: Select None or ARINC 429.
b.
ARINC 429 Bus Speed
: If the source selected is ARINC 429 select Low (12.0 to 14.5 Kbps) or
High (100 kbps) bus speed.
2.
Altitude
a.
Source
: Select from one of the following:
•
ARINC 429
•
RS-232 Altitude Encoder Port
•
RS-232 Control Panel Port
•
Gilham Interface
b.
Protocol
: These options are available only when the selected source is “RS-232 Altitude
Encoder Port”.
c.
RS-232 Baud Rate
: These options are available only when the selected source is “RS-232
Altitude Encoder Port” or “RS-232 Control Panel Port”.
d.
ARINC 429 Bus Speed
: If the source selected is ARINC 429 select Low (12.0 to 14.5 Kbps) or
High (100 kbps) bus speed.
e.
Resolution (ft)
: Select >25 or <=25 based on the encoder increment rate.
3.
Click on the Apply button after all information is entered. This information is saved to the
configuration module.
0040-17001-01
Installation Checkout
Page 3-13
Revision A
January 15, 2015