Lynx NGT-9000s
Installation Manual
Table 4-3: List of Fault Log Messages
FAULT ID/ CODE
(HEX)
FAULT DESCRIPTION
CORRECTIVE ACTION
0x0000100D
Map DB Flash CRC Failure
Map database failure
FIS-B internal degraded
Reboot the unit and check if the fault
persists. May need to update or load map
database data.
Contact L-3 Field Service before removal.
0x0000100E
Map DB Flash Compatibility Failure
Map database failure
FIS-B internal degraded
Reboot the unit and check if the fault
persists. May need to update or load map
database data.
Contact L-3 Field Service before removal.
0x00001011
Operational SW RAM CRC Failure
Failure causes a reset
Log the fault.
0x00001012
Airport DB RAM CRC Failure
Failure causes a reset
Reboot the unit and check if the fault
persists. May need to update or load
airport database data.
Contact L-3 Field Service before removal.
0x00001013
Map DB RAM CRC Failure
Failure causes a reset
Log the fault.
0x00001015
Factory Data RAM CRC Failure
Failure causes a reset
Log the fault.
0x00001016
Config Data RAM CRC Failure
Failure causes a reset
Reboot the unit and check if the fault
persists. Contact L-3 Field Service before
removal.
0x00001017
Factory Data NVM CRC Failure
Failure causes a reset
Reboot the unit and check if the fault
persists. Contact L-3 Field Service before
removal.
0x00001018
Factory Data Compatibility Failure
Failure causes a reset
Reboot the unit and check if the fault
persists. Contact L-3 Field Service before
removal.
0x00001019
Config Data NVM CRC Failure
Failure causes a reset
Reboot the unit and check if the fault
persists. Contact L-3 Field Service before
removal.
0x0000101A
Config Data NVM Compatibility
Failure
Failure causes a reset
Reboot the unit and check if the fault
persists. Contact L-3 Field Service before
removal.
0x0000101B
Power Loss In Air
Check Table 4-1 or Table 4-2
0x0000101C
Ambient Light Sensor Failure
Reboot the unit and check if the fault
persists. Contact L-3 Field Service before
removal.
0x00001801
Clear Oscillator Synthesizer Out of
Lock
Reboot the unit and check if the fault
persists. Contact L-3 Field Service before
removal.
0x00001802
Clear Mutual Supp Bus Failed to
Assert
Reboot the unit and check if the fault
persists. Contact L-3 Field Service before
removal.
0x00001803
Clear Mutual Supp Bus Stuck High
Reboot the unit and check if the fault
persists. Contact L-3 Field Service before
removal.
0040-17001-01
Maintenance
Page 4-21
Revision A
January 15, 2015