Table 1-3: Specifications for Lynx NGT-9000s
OPERATING TEMPERATURE:
-20
°
to +55
°
C (-4
°
to +131
°
F)
STORAGE TEMPERATURE:
-55
°
to +85
°
C (-67
°
to +185
°
F)
MAXIMUM ALTITUDE:
55,000 ft (installation environment)
FUNCTIONALITY:
•
Mode S Transponder
•
Global Positioning System (GPS)
•
UAT/1090ES ADS-B In
•
1090ES ADS-B Out: Automatic Dependent Surveillance – Broadcast
•
Traffic Awareness System (TAS) (optional)
OPERATION:
Start Up Time:
On Ground 20 seconds or less
In air 5 seconds or less.
Display Luminance:
Range 0.05 fl to 150 fl
Built In Test:
Fault Monitoring on all stages of operation from start up to
power down.
UAT Receiver Sensitivity
(Class A1S)
-95.0dBm for 90% Message Decoding for Long ADS-B
Messages
-96.0dBm for 90% Message Decoding for Short ADS-B
Messages
-93.0dBm for 90% Message Decoding for Ground Uplink
Messages
Mode S Transponder Power
(Class 1 Transponder). 125W minimum, 250 W maximum.
TAS Output Power
(Class A TAS). 125W minimum, 250 W maximum.
SCHEDULED MAINTENANCE:
The Lynx NGT-9000s is a transponder device and must be tested and inspected every 24
months subject to the requirements of FAA documents 14 CFR Part 43 Appendix F.
SERVICE LIFE:
The Lynx NGT-9000s has unlimited service life.
REPAIRABILITY:
Repairs performed at the FAA certificated Repair Station co-located at the OEM
(equipment) facility.
0040-17001-01
General Information
Page 1-13
Revision A
January 15, 2015